کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
505376 864499 2014 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A computational pipeline for quantification of mouse myocardial stiffness parameters
ترجمه فارسی عنوان
یک خط لوله محاسباتی برای اندازه گیری پارامترهای سختی قلب ماوس
موضوعات مرتبط
مهندسی و علوم پایه مهندسی کامپیوتر نرم افزارهای علوم کامپیوتر
چکیده انگلیسی


• Deformation of passively inflated mouse heart was measured with echo speckle tracking.
• The observed deformation was compared with simulations of a finite element model.
• Simulations spanned the range of published parameter estimates.
• Two lack-of-fit criteria were tried: node positions or gross phenotypes.
• Estimation turned out to be more precise when based on changes in gross phenotypes.

The mouse is an important model for theoretical–experimental cardiac research, and biophysically based whole organ models of the mouse heart are now within reach. However, the passive material properties of mouse myocardium have not been much studied.We present an experimental setup and associated computational pipeline to quantify these stiffness properties. A mouse heart was excised and the left ventricle experimentally inflated from 0 to 1.44 kPa in eleven steps, and the resulting deformation was estimated by echocardiography and speckle tracking. An in silico counterpart to this experiment was built using finite element methods and data on ventricular tissue microstructure from diffusion tensor MRI. This model assumed a hyperelastic, transversely isotropic material law to describe the force–deformation relationship, and was simulated for many parameter scenarios, covering the relevant range of parameter space. To identify well-fitting parameter scenarios, we compared experimental and simulated outcomes across the whole range of pressures, based partly on gross phenotypes (volume, elastic energy, and short- and long-axis diameter), and partly on node positions in the geometrical mesh. This identified a narrow region of experimentally compatible values of the material parameters. Estimation turned out to be more precise when based on changes in gross phenotypes, compared to the prevailing practice of using displacements of the material points. We conclude that the presented experimental setup and computational pipeline is a viable method that deserves wider application.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Computers in Biology and Medicine - Volume 53, 1 October 2014, Pages 65–75
نویسندگان
, , , , , , , , , , , , , , , ,