کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5114353 1484391 2017 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Experimental investigation of a modular wind tower in hot and dry regions
ترجمه فارسی عنوان
بررسی تجربی یک برج بادی مدولار در مناطق گرم و خشک
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی (عمومی)
چکیده انگلیسی
Passive cooling systems such as wind towers or wind catchers can create thermal comfort for building residents in hot and dry regions. This paper introduces an experimental study of a modular design of wind tower called the modular wind tower with wetted surfaces. Air temperature, relative humidity (RH) and airflow velocity parameters were measured at different times and at points when the velocity of the ambient air was zero. The results show that the modular wind tower can decrease the air temperature by an average of 10 °C and increase the relative humidity of airflow in a building by approximately 36% on average. Additionally, the wind tower can create the airflow velocity entering the building up to around 1.8 m/s. Furthermore, the obtained data from the measurements illustrate that the conditions of indoor air improve to the thermal comfort conditions.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy for Sustainable Development - Volume 39, August 2017, Pages 21-28
نویسندگان
, , ,