کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
534583 870267 2013 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Automatic detection of vascular bifurcations in segmented retinal images using trainable COSFIRE filters
موضوعات مرتبط
مهندسی و علوم پایه مهندسی کامپیوتر چشم انداز کامپیوتر و تشخیص الگو
پیش نمایش صفحه اول مقاله
Automatic detection of vascular bifurcations in segmented retinal images using trainable COSFIRE filters
چکیده انگلیسی

Background: The vascular tree observed in a retinal fundus image can provide clues for cardiovascular diseases. Its analysis requires the identification of vessel bifurcations and crossovers.Methods: We use a set of trainable keypoint detectors that we call Combination Of Shifted FIlter REsponses or COSFIRE filters to automatically detect vascular bifurcations in segmented retinal images. We configure a set of COSFIRE filters that are selective for a number of prototype bifurcations and demonstrate that such filters can be effectively used to detect bifurcations that are similar to the prototypical ones. The automatic configuration of such a filter selects given channels of a bank of Gabor filters and determines certain blur and shift parameters. The response of a COSFIRE filter is computed as the weighted geometric mean of the blurred and shifted responses of the selected Gabor filters. The COSFIRE approach is inspired by the function of a specific type of shape-selective neuron in area V4 of visual cortex.Results: We ran experiments on three data sets and achieved the following results: (a) a recall of 97.88% at precision of 96.94% on 40 manually segmented images provided in the DRIVE data set, (b) a recall of 97.32% at precision of 96.04% on 20 manually segmented images provided in the STARE data set, and (c) a recall of 97.02% at precision of 96.53% on a set of 10 automatically segmented images obtained from images in the DRIVE data set.Conclusions: The COSFIRE filters that we use are conceptually simple and easy to implement: the filter output is computed as the weighted geometric mean of blurred and shifted Gabor filter responses. They are versatile keypoint detectors as they can be configured with any given local contour pattern and are subsequently able to detect the same and similar patterns.


► We use COSFIRE filters to detect vascular bifurcations in retinal fundus images.
► A COSFIRE output is the product of blurred and shifted Gabor filter responses.
► We obtain recall of 97.88% and precision of 96.94% on 40 images (>5000 bifurcations).
► Trainable COSFIRE filters are versatile and effective keypoint detectors.
► COSFIRE filters are conceptually simple and easy to implement.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Pattern Recognition Letters - Volume 34, Issue 8, 1 June 2013, Pages 922–933
نویسندگان
, ,