کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5428618 1508685 2013 19 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Verification of the H2O linelists with theoretically developed tools
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه شیمی طیف سنجی
پیش نمایش صفحه اول مقاله
Verification of the H2O linelists with theoretically developed tools
چکیده انگلیسی


- Spectroscopic parameters of H2O lines in the same groups follow the two basic rules.
- By screening data with the rules, one is able to identify errors existing in HITRAN.
- Missing lines in linelists whose intensities are above a threshold can be identified.
- Advices how to select data from multiple sources in developing HITRAN are provided.
- The study enables one to significantly improve the accuracy of the H2O database.

Two basic rules (i.e., the pair identity and the smooth variation rules) resulting from the properties of the energy levels and wave functions of H2O states govern how the spectroscopic parameters vary with the H2O lines within the individually defined groups of lines. With these rules, for those lines involving high j states in the same groups, variations of all their spectroscopic parameters (i.e., the transition frequency, intensity, pressure broadened half-width, pressure-induced shift, and temperature exponent) can be well monitored. Thus, the rules can serve as simple and effective tools to screen the H2O spectroscopic data listed in the HITRAN database and verify the latter's accuracies. By checking violations of the rules occurring among the data within the individual groups, possible errors can be picked up and also possible missing lines in the linelist whose intensities are above the threshold can be identified. We have used these rules to check the accuracies of the spectroscopic parameters and the completeness of the linelists for several important H2O vibrational bands. Based on our results, the accuracy of the line frequencies in HITRAN 2008 is consistent. For the line intensity, we have found that there are a substantial number of lines whose intensity values are questionable. With respect to other parameters, many mistakes have been found. The above claims are consistent with a well known fact that values of these parameters in HITRAN contain larger uncertainties. Furthermore, supplements of the missing line list consisting of line assignments and positions can be developed from the screening results.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Quantitative Spectroscopy and Radiative Transfer - Volume 130, November 2013, Pages 81-99
نویسندگان
, , , ,