کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5429264 1397342 2012 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Effect of process parameters on temperature distribution in twin-electrode TIG coupling arc
موضوعات مرتبط
مهندسی و علوم پایه شیمی طیف سنجی
پیش نمایش صفحه اول مقاله
Effect of process parameters on temperature distribution in twin-electrode TIG coupling arc
چکیده انگلیسی

The twin-electrode TIG coupling arc is a new type of welding heat source, which is generated in a single welding torch that has two tungsten electrodes insulated from each other. This paper aims at determining the distribution of temperature for the coupling arc using the Fowler-Milne method under the assumption of local thermodynamic equilibrium. The influences of welding current, arc length, and distance between both electrode tips on temperature distribution of the coupling arc were analyzed. Based on the results, a better understanding of the twin-electrode TIG welding process was obtained.

► Increasing arc current will increase the coupling arc temperature. ► Arc length seldom affects the peak temperature of the coupling arc. ► Increasing arc length will increase the extension of temperature near the anode. ► Increasing distance will decrease temperatures in the central part of the arc.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Quantitative Spectroscopy and Radiative Transfer - Volume 113, Issue 15, October 2012, Pages 1938-1945
نویسندگان
, , , ,