کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5430496 1397406 2008 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Particle effects on the emissivity and temperature of optically thick, mixed media retrieved by mid-IR emission spectroscopy
موضوعات مرتبط
مهندسی و علوم پایه شیمی طیف سنجی
پیش نمایش صفحه اول مقاله
Particle effects on the emissivity and temperature of optically thick, mixed media retrieved by mid-IR emission spectroscopy
چکیده انگلیسی

Passive diagnostics offer new ways of obtaining real-time data for the control and modeling of industrial furnaces. It has been proposed elsewhere that from the intensity profile between 3.8 and 4.7 μm one may derive the temperature of a gas-particle medium and the particle emissivity (εp) at 3.95 μm. This technique applies to large columns of combustion products with enough CO2. The temperature is retrieved by finding the best fit between Planck's function and the intensity profile between 4.56 and 4.7 μm, which is that of a blackbody due to CO2 saturation. Here we consider the effect of particles on the intensity profile and, therefore, on the retrieved temperature and particle emissivity. We derive an analytic approximation of the effective emissivity for an optically thick gas-particle mixture that includes emission and absorption due to particles and gases, along with isotropic particle scattering. The derivation follows the method of embedded invariance and has been used already for particle-only clouds. It yields a spectral solution that is applicable in other infrared regions where gas and particle optical thicknesses are large. A key parameter (χ) is the ratio of the gas absorption coefficient to the particle extinction coefficient. For χ=1 and εp=0.5, particle effects decrease the gas band profile by 5% from that of a blackbody. For χ<1 and εp<0.5, particle effects on the calculated temperature and particle emissivity are noticeable and particle effects should be considered. If χ is known, an iterative procedure may be used to calculate temperature and particle emissivity. We illustrate this procedure with data from a coal-fired boiler. Accounting for particle effects, temperatures were 4% higher (at about 1500 K) and particle emissivities 28% lower (for εp within 0.3-05) than without considering these effects.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Quantitative Spectroscopy and Radiative Transfer - Volume 109, Issue 7, May 2008, Pages 1325-1334
نویسندگان
, ,