Thermoluminescence measurements of trap depth in alkali feldspars extracted from bedrock samples
ترجمه فارسی عنوان
اندازه گیری ترمولومینسانس عمق دام در فلدسپارهای قلیایی استخراج شده از نمونه های بستر
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
چکیده انگلیسی
Various measurements of thermal trap depth are evaluated for K-feldspar grains extracted from a bedrock sample. The initial rise method and the various heating rates method yield consistent results for both the natural signal (E = 1.23 and 1.16 eV, respectively) and for a regenerative dose of 64 Gy (0.83 and 0.78 eV). For the fractional glow curve, apparent E-values range from 0.39 eV to a plateau around 1.50 eV. The highest values for the natural and regenerative signals are obtained using the newly-developed post-isothermal TL (pI-TL) method wherein the isothermal loss curves (gotten by subtracting TL curves obtained after different preheat durations) are fitted in the initial rise region on an Arrhenius plot. For a dose of 12.8 Gy, this method measures apparent E-values ranging from 0.73 eV to a plateau near 1.84 ± 0.06 eV. We repeat this analysis on three additional feldspar samples (two perthites and a high albite) to get a mean value of E = 1.86 ± 0.03 eV. The same analysis of natural aliquots of the K-feldspar sample yields similar results, with the two highest E-values at 1.81 and 1.86 eV. The kinetic order does not systematically vary with isothermal holding temperature or duration but remains relatively constant at 1.6 ± 0.3 (regenerative dose) and 1.5 ± 0.5 (natural dose). The apparent frequency factor, measured assuming a single E-value of 1.86 eV, decreases systematically (∼1023−1012s−1) with hold temperature and duration, a result which is consistent with a thermally-activated, distance-dependent tunneling model for feldspar thermoluminescence (i.e., a single trap depth and a continuum of apparent frequency factors). Frequency factor values measured following identical isothermal treatments are comparable between the natural and regenerative post-isothermal TL curves. By contrast, if different E-values are assumed, the apparent frequency factor values appear stochastic. Finally, it is speculated that the plateau of pI-TL E-values may be interpreted as the thermal depth of the main dosimetric trap measured with IRSL protocols.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Radiation Measurements - Volume 96, January 2017, Pages 53-61
نویسندگان
, ,