کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5743604 1617996 2017 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Performance study of biofilter system for on-site greywater treatment at cottages and small households
ترجمه فارسی عنوان
بررسی عملکرد سیستم بیوفیلتر برای درمان خاکستری در محل در کلبه ها و خانوارهای کوچک
کلمات کلیدی
جداسازی منبع، رویکرد چند مرحله ای، جارو برقی، نفوذ خاک،
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم کشاورزی و بیولوژیک بوم شناسی، تکامل، رفتار و سامانه شناسی
چکیده انگلیسی


- Source separation and multi-barrier biofilter system is used.
- Source-separation markedly reduced organic matter, suspended solids and nutrients.
- Effluent quality complies with the Norwegian discharge limits.
- Post polishing significantly reduced effluent microbial concentration.

The current contribution of microbial pathogens and nutrient discharge into the environment from inefficient on-site wastewater treatment systems has raised concern in many areas due to the pollution of the nearby water recipient. To overcome this challenge, a novel and more robust proven treatment systems are required. This paper aims to assess the performance of a source separating wastewater management system for the removal of organic matter, total P, total suspended particles and E. coli. The system is a multi-stage approach including - a separate collection of blackwater (BW) and greywater, followed by on-site greywater treatment system in a fixed-film biofilter and finally a soil infiltration system used as a polishing step before discharging into the environment. The separation and collection of BW resulted a notable reduction for chemical oxidation demand (COD), biochemical oxidation demand (BOD), total suspended solids (TSS), nitrogen (N) and phosphorus (P) accounting for 64%, 61%, 75%, 85 and 88%, respectively. The overall removal efficiency of the system for the above-mentioned parameters reached over 90% at the biofilter effluent and more than 95% at the bottom of the constructed infiltration column. For coliform bacteria and E. coli, the overall system reached a reduction of 4-5 log10 units of which the major reduction was observed in the infiltration columns. The effluent quality from this source-separating and multi-barrier biofilter treatment system complies with the Norwegian discharge limits. The assessment results reveal that this system can be used in drinking water source catchments with minimum environmental and health related risks.

44

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Ecological Engineering - Volume 105, August 2017, Pages 118-124
نویسندگان
, , , ,