کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
5744041 | 1618001 | 2017 | 6 صفحه PDF | دانلود رایگان |
- Determination of yield coefficients in CW using a static respirometer is presented.
- Three different types of OUR profiles were identified with different biomass behaviour.
- Initial yield ranged 0.41-0.67 and storage yield ranged 0.75-0.83Â gCODÂ gCODâ1.
- The proposed method will allow analysing samples from CW field units.
This study investigated the possibility of measuring yield coefficient values for the biomass of a laboratory-scale horizontal sub-surface flow constructed wetland (HSSF-CW) using a static respirometer. The respirometric tests used 300Â mL bulk volume of biomass-laden gravel samples from the HSSF-CW, from which the biomass was detached by a vigorous washing with 1Â L of tap water. The presented tests were performed using sodium acetate as standard substrate and had a duration of 6-21Â h. The obtained value ranges for initial yield and storage yield were, respectively, 0.41-0.67 and 0.75-0.83 (gCODÂ gCODâ1), comprising the literature ranges reported for activated sludge and vertical flow constructed wetlands.
Journal: Ecological Engineering - Volume 98, January 2017, Pages 388-393