کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5797695 1111758 2015 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Influence of experimental protocol on response rate and repeatability of mechanical threshold testing in dogs
ترجمه فارسی عنوان
تأثیر پروتکل تجربی بر میزان پاسخ و تکرارپذیری آزمایش آستانه مکانیکی در سگ ها
کلمات کلیدی
سگ بیماری مفصلی تخریب شده غربالگری، آستانه مکانیکی، بررسی پروتکل،
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم کشاورزی و بیولوژیک علوم دامی و جانورشناسی
چکیده انگلیسی


- Mechanical nociceptive thresholds were obtained from healthy dogs.
- Effect of protocol on success rate, repeatability and threshold was examined.
- Stimulus area, position of dog and anatomical site affected success rate.
- Wider stimulus areas were associated with higher thresholds.
- Between dog variation had a greater effect than protocol on all three outcomes.

Mechanical threshold (MT) testing is widely used to measure nociceptive thresholds. However, there has been little research into factors that contribute to the response rate and repeatability (collectively termed 'efficacy') of MT testing protocols. The aim of this study was to investigate whether the efficacy of a protocol using a hand-held algometer to measure MTs (N) in healthy dogs (n = 12) was affected by varying (1) the area over which force was applied (tip diameter), (2) rate of force application, (3) position of dog during testing, and (4) anatomical site of testing. The effect of these factors on MT and the impact of individual dog effects on both efficacy and MT were also investigated.Overall, 3175/3888 tests (82%) resulted in a measurable response. The response rate was reduced by using wider tip diameters, testing at the tibia, and testing when the dog was lying down (compared to sitting upright). Wider tips were associated with higher, more variable MTs (mean ± standard deviation) with values of 4.18 ± 2.55 N for 2 mm diameter tips, 5.54 ± 3.33 for those of 4 mm, and 7.59 ± 4.73 for 8 mm tips. Individual dog effects had the most significant impact on efficacy and MT. The findings indicate that tip diameter, dog position, and anatomical site may affect both protocol efficacy and MTs, and should be taken into account when comparing different studies and in designing protocols to measure MTs in dogs. The predominant effect of the individual dog over other factors indicates that between-subject differences should always be accounted for in future studies.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Veterinary Journal - Volume 204, Issue 1, April 2015, Pages 82-87
نویسندگان
, , , ,