کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
612283 880694 2007 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Quartz resonator signatures under Newtonian liquid loading for initial instrument check
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی شیمی کلوئیدی و سطحی
پیش نمایش صفحه اول مقاله
Quartz resonator signatures under Newtonian liquid loading for initial instrument check
چکیده انگلیسی

The quartz crystal microbalance (QCM) has been increasingly utilized in the monitoring of the deposition of thin macromolecular films. Studies in the deposition of polymers, biomaterials, and interfacial reactions under electrochemical environment are some of the conditions for the study of these material and deposition properties at a lipid interface. Numerous studies have shown the difficulties in configuring an experimental setup for the QCM such that the recorded data reflect only the behavior of the quartz crystal and its load, and not some artifact. Such artifacts for use in liquids include mounting stress, surface properties such as hydrophobicity, surface roughness coupling to loading liquids, influence of compressional waves, and even problems with the electronic circuitry including the neglect of the quartz capacitance and the hysteretic effects of electronic components. It is thought useful to obtain a simple test by which the user could make a quick initial assessment of the instrument's performance. When a smooth quartz crystal resonator is immersed from air into a Newtonian liquid, the resonance and loss characteristics of the QCM are changed. A minimum of two experimental parameters is needed to characterize these changes. One of the changes is that of the resonant frequency. The second is characterized by either a change in the equivalent circuit resistance (ΔR) or a change in the resonance dissipation (ΔD). Two combinations of these observables, in terms of either Δf and ΔR or Δf and ΔD  , which we define as Newtonian signatures of S1S1 and S2S2, are calculated to have fixed values and to be independent of the harmonic and of the physical values of the Newtonian liquid. We have experimentally determined the values of S1S1 and S2S2 using three different QCM systems. These are the standard oscillator, the network analyzer, and the QCM dissipation instrument. To test the sensitivity of these signatures to surface roughness, which is potential experimental artifact, we determined the values of S1S1 and S2S2 for roughened crystals and found that these signatures do reflect that experimental condition. Moreover, these results were qualitatively in accord with the roughness scaling factor described by Martin.

The topography of crystals was measured by AFM that had roughness of ∼2, ∼300, and ∼600 nm∼600 nm, respectively.Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Colloid and Interface Science - Volume 315, Issue 1, 1 November 2007, Pages 248–254
نویسندگان
, , , , , ,