کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
654254 885236 2008 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A three-dimensional performance analysis of all-glass vacuum tubes with coaxial fluid conduit
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
پیش نمایش صفحه اول مقاله
A three-dimensional performance analysis of all-glass vacuum tubes with coaxial fluid conduit
چکیده انگلیسی

The thermal performance of a solar system composed of parallel, all-glass (double skin) vacuum tubes has been investigated by using a three-dimensional analytical model. Each vacuum tube is equipped with a coaxial fluid conduit for water to flow through and collect the sun's thermal energy. The space between the exterior of the fluid conduit and the glass tube is filled with antifreeze solution to facilitate heat transfer from the solar heated absorber surface to water and to prevent the functional problems due to freezing in frigid weather conditions. Different from one-dimensional analytical models, the three-dimensional model considered in the present analysis enables the prediction of spatial variation of water temperatures as it flows through the coaxial conduit. This is quite useful in extracting major variables for the operation of the solar system using all-glass vacuum tubes as considered in the present investigation.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Communications in Heat and Mass Transfer - Volume 35, Issue 5, May 2008, Pages 589–596