کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6589597 456849 2015 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Laminar mixing in a SMX static mixer evaluated by positron emission particle tracking (PEPT) and magnetic resonance imaging (MRI)
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی مهندسی شیمی (عمومی)
پیش نمایش صفحه اول مقاله
Laminar mixing in a SMX static mixer evaluated by positron emission particle tracking (PEPT) and magnetic resonance imaging (MRI)
چکیده انگلیسی
Static mixers are implemented across many industries and are used for mixing, heating and reacting processes. This paper reports the combined use of positron emission particle tracking (PEPT) and magnetic resonance imaging (MRI) to assess mixing in the industrially important SMX static mixer geometry. The focus of this study was distributive mixing for a Newtonian fluid, glycerol, flowing in the laminar regime in the standard SMX static mixer. By implementing PEPT and MRI techniques, the work elucidated mixing indices that incorporate both local velocities and concentration fields within the structure of the mixer element at 0.5 mm intervals over a length of nine 1.0L/D SMX elements. The experimental results are placed in context with previously published computational studies for this geometry.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Chemical Engineering Science - Volume 137, 1 December 2015, Pages 1014-1023