کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
667831 | 1458597 | 2007 | 10 صفحه PDF | دانلود رایگان |

This paper provides data on the split of liquid/liquid two-phase flow at a horizontal T-junction. Phase maldistribution was measured for kerosene–water flow at the T-junction with equal pipe diameters of 67.4 mm. Data were taken with both stratified flow with a mixture at interface and dispersed flows approaching the junction. The degree of phase maldistribution was not very great but preferential emergence of either phase from the side-arm was observed depending on the flow rates of the two-phases. There are similarities with the limited split data from liquid/solid flows and the degree of separation is seen to depend on the dispersed/continuous phase density ratio. The data were compared to predictions from the correlation by Seeger et al. The Seeger equation gives but reasonable agreement.
Journal: International Journal of Multiphase Flow - Volume 33, Issue 2, February 2007, Pages 207–216