کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
672419 887502 2011 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Numerical simulation of micro-particle deposition in a realistic human upper respiratory tract model during transient breathing cycle
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
پیش نمایش صفحه اول مقاله
Numerical simulation of micro-particle deposition in a realistic human upper respiratory tract model during transient breathing cycle
چکیده انگلیسی

An more reliable human upper respiratory tract model that consisted of an oropharynx and four generations of asymmetric tracheo-bronchial (TB) airways has been constructed to investigate the micro-particle deposition pattern and mass distribution in five lobes under steady inspiratory condition in former work by Huang and Zhang (2011). In the present work, transient airflow patterns and particle deposition during both inspiratory and expiratory processes were numerically simulated in the realistic human upper respiratory tract model with 14 cartilaginous rings (CRs) in the tracheal tube. The present model was validated under steady inspiratory flow rates by comparing current results with the theoretical models and published experimental data. The transient deposition fraction was found to strongly depend on breathing flow rate and particle diameter but slightly on turbulence intensity. Particles were mainly distributed in the high axial speed zones and traveled basically following the secondary flow. “Hot spots” of deposition were found in the lower portion of mouth cavity and posterior wall of pharynx/larynx during inspiration, but transferred to upper portion of mouth and interior wall of pharynx/larynx during expiration. The deposition fraction in the trachea during expiration was found to be much higher than that during inspiration because of the stronger secondary flow.

The simulated particle transient deposition fraction strongly depended on breathing flow rate and particle diameter but slightly on turbulence intensity. Particles were mainly distributed in the high axial speed zones and traveled basically following the secondary flow. Simulation results show that the axial symmetric assumption of tracheal inlet boundary condition needs to be reconsidered while the separated lung model is adopted.Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Particuology - Volume 9, Issue 4, August 2011, Pages 424–431
نویسندگان
, ,