کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
6729425 | 1428932 | 2018 | 28 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Thermal and ventilation performance of combined passive chilled beam and displacement ventilation systems
ترجمه فارسی عنوان
عملکرد حرارتی و تهویه از سیستم های هوای مخفی منافذ مخلوط و سیستم تهویه جابجایی
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
راحتی حرارتی، سن هوا، اثربخشی تهویه گرادیان دما عمودی، دینامیک سیالات محاسباتی،
موضوعات مرتبط
مهندسی و علوم پایه
مهندسی انرژی
انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
چکیده انگلیسی
Chilled beams provide sensible cooling to an occupied space by using chilled water flowing through modular beams mounted to a room ceiling. Previous studies show that active chilled beam systems can achieve larger sensible cooling than all-air systems. However, most studies have focused on active chilled beams and little information is available for performance of passive chilled beam (PCB) under varied ventilation conditions. The objective of the present study is to investigate ventilation and air conditioning performance of combined PCB and displacement ventilation systems. Using a validated and verified computational fluid dynamics (CFD) model, parametric analyses were performed to examine the ventilation and air conditioning performance depending on five major operating parameters: 1) ventilation strategy, 2) PCB cooling output, 3) supply air temperature, 4) supply diffuser type, and 5) internal heat source arrangement. The results show that thermal comfort and ventilation performance of a combined PCB-DV system notably vary with the PCB cooling output and supply air temperature. When the PCB cooling output increases from 33% to 53% of the total cooling load, air change effectiveness decreases from 1.6 to 1.2 and vertical temperature difference decreases from 4.0 °C to 1.5 °C in the breathing zone. However, spatial heat source distribution has a marginal effect on the air mixing and temperature distribution. The results suggest that a relatively high PCB cooling output (>50% of the total cooling) combined with a low supply air temperature (e.g., 17 °C) could disrupt thermal stratification of displacement ventilation and increase draft rate in the occupied zone.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy and Buildings - Volume 158, 1 January 2018, Pages 466-475
Journal: Energy and Buildings - Volume 158, 1 January 2018, Pages 466-475
نویسندگان
Wenyu Shan, Donghyun Rim,