کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
708328 891982 2015 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A methodology to quantify the uncertainty in liquid holdup measurements with wire mesh sensor
ترجمه فارسی عنوان
یک روش برای اندازه گیری عدم قطعیت در اندازه گیری مابقی مایع با حسگر سیم مش
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی کنترل و سیستم های مهندسی
چکیده انگلیسی


• The uncertainty in liquid holdup measurements of Wire Mesh Sensors is evaluated.
• A methodology is proposed for the quantification of measurement uncertainty.
• Uncertainty in laboratory tests represent in-situ conditions.
• For holdup values up to 15%, uncertainty increases logarithmically to 1.5%.
• For holdup values larger than 15%, the uncertainty is limited to 1.5%.

The uncertainty in the holdup measurements of a capacitance based WMS with 32×32 wires has been experimentally evaluated, and a methodology for its quantification is proposed for horizontal flow. Investigation is performed in laboratory and in-situ experiments under stagnant conditions with an emphasis on the effect of the mesh grid orientation on the measurements. Also, potential impact of misalignment in the pipe inclination is explored by slightly inclining the pipe for both tests. Finally, dynamic flow conditions are tested in a high pressure (1.37 MPa) facility with horizontal stratified-wavy oil/air two-phase flow for gas and liquid superficial velocity ranges of 2.8 m/s≤νSg≤6.9 m/s and 0.01 m/s≤vSL≤0.05 m/s, respectively.The angle between the phase interface and the sensor wires is ineffective while the misalignment in the pipe inclination plays a major role in the deviations of the holdup measurements. Using the proposed methodology, the measurement uncertainty from laboratory tests is shown to follow a logarithmic increase as a function of the measured holdup for smaller holdup values (HL≤15%) and to be lower than 1.5% for HL>15%. This behavior is intrinsic to WMS and a representative of the measurement uncertainty in the actual flow loop installation.Under actual flow conditions, the holdup measurements of the trapped liquid by WMS show an offset compared to the measurements via flow imaging which can be corrected by using the uncertainty quantified in the laboratory tests. However, the dynamic measurements with WMS show a good agreement with the holdup of the trapped liquid volume within the quantified uncertainty bounds.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Flow Measurement and Instrumentation - Volume 46, Part A, December 2015, Pages 18–24
نویسندگان
, , , , , ,