The humidity effect on air flow rates in a critical flow venturi nozzle
چکیده انگلیسی

A Critical Flow Venturi Nozzle (CFVN) is usually calibrated using dry air. Yet CFVNs in industrial and calibration service centers are often used to measure flow rates of humid air. Therefore, ISO 9300 provides the calculation method for the humidity effect on discharge coefficients of CFVN. However, since this method is only due to a theoretical analysis, it is important to confirm and check the ISO calculation method for the humidity effect on CFVN with its isentropic analysis by means of an experimental method.In this experiment, three CFVNs with diameters of 0.4, 0.8 and 1.6 mm were calibrated with dry air (with the dew point −40 °C), in a primary air flow standard system with a mercury sealed piston prover, installed at the Korea Research Institute of Standards and Science (KRISS). Another piston prover, a portable dry piston prover, was used as a reference meter and was also calibrated in the primary standard system using dry air. The repeatability of this dry piston prover was confirmed with the deviation being less than 0.05%. The CFVNs were tested with this dry piston prover, using humid air. For air types with high humidity, the humidity effect on flow rates through the CFVNs showed quite significant difference between the experimental results and those from the ISO method with isentropic analysis. But for air types with low humidity, its effect was relatively insignificant.


► Experimental study on the humidity correction of the discharge coefficients of critical flow Venturi nozzles.
► Test of three critical flow Venturi nozzles with air at the relative humidity from 0% to 90%.
► The correlation as a function of the molar fraction of water vapor at the uncertainty of 0.16%.
► Further study on the humidity effect for the modification of a correlation given in ISO 9300.