کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
708594 | 1461115 | 2009 | 16 صفحه PDF | دانلود رایگان |

Differential pressure (DP) meters which utilise a cone as the system’s primary element are increasingly being used to measure wet natural gas flows (i.e. mixtures of natural gas, light hydrocarbon liquids and water). It is therefore important to understand this meter’s response to wet natural gas flows. Research into the wet gas response of the horizontally installed cone DP meter is discussed in this paper. Consideration is given to the significant influence of the liquid properties on wet gas flow patterns and the corresponding influence of the flow pattern on the cone DP meter’s liquid phase induced gas flow rate prediction error. A wet natural gas flow correlation for 4 in. 0.75 beta ratio cone DP meters with natural gas, hydrocarbon liquid and water flow has been developed from multiple data sets from three different wet gas flow test facilities. This corrects the liquid induced gas flow rate prediction error of a wet gas flow up to a Lockhart–Martinelli parameter of 0.3, for a known liquid flow rate of any hydrocarbon liquid/water ratio, to ±4% at a 95% confidence level.
Journal: Flow Measurement and Instrumentation - Volume 20, Issues 4–5, August–October 2009, Pages 152–167