کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
7175514 1466408 2015 41 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
An experimental investigation of refrigerant mixture R32/R290 as drop-in replacement for HFC410A in household air conditioners
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی مکانیک
پیش نمایش صفحه اول مقاله
An experimental investigation of refrigerant mixture R32/R290 as drop-in replacement for HFC410A in household air conditioners
چکیده انگلیسی
In the present paper, the refrigerant mixture R32/R290 (68%/32% by weight) is investigated as the drop-in replacement for R410A in household air conditioners. The GWP of it is only 22% of that of R410A. Theoretical and experimental investigations are conducted on the performance of the air conditioners working with both R32/R290 and R410A. Experimental results show that the refrigerant charge amount of R32/R290 is reduced by 30.0%-35.0%; the cooling and heating capacities are increased by 14.0%-23.7%. For further reducing charge amount and flammability, the micro-channel heat exchanger (condenser) is employed to replace the finned tube one. Compared with the R32/R290 system using finned tube heat exchanger, the R32/R290 charge amount and the power consumption are reduced by 34.1% and 0.4%, respectively; the cooling capacity and the COP are increased by 6.4% and 6.8%, respectively.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Refrigeration - Volume 57, September 2015, Pages 216-228
نویسندگان
, , , , , , ,