کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
721856 | 892319 | 2006 | 6 صفحه PDF | دانلود رایگان |

Knock detection occupies a very important role in the ignition control of a Spark Ignition (S.I.) engine. Production-grade knock detection schemes must be computationally efficient and comprise a set of parameters which require calibration during Engine Control Unit (ECU) development. This is typically achieved empirically, whereby a calibration engineer induces knock on the ECU and monitors the detection performance to manually adjust the tunable parameters. In this paper, we propose automatic, on-line calibration of a production-grade, frequency-domain knock detection system. Compared to the conventional method of manual calibration, this method allows for on-line tuning of the parameters based on scientific optimization schemes. It thus enables the implementation of specific objective functions which can meet desired criteria.
Journal: IFAC Proceedings Volumes - Volume 39, Issue 16, 2006, Pages 324–329