کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
724808 892429 2006 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Flow distribution and pressure of air due to ionic wind in pin-to-plate corona discharge system
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی برق و الکترونیک
پیش نمایش صفحه اول مقاله
Flow distribution and pressure of air due to ionic wind in pin-to-plate corona discharge system
چکیده انگلیسی

An electrohydrodynamic investigation has been carried out in a pin-to-plate gas discharge system to clarify the mechanism of repulsive force generation between a pin and plate electrode at corona discharge. Numerical calculations have been conducted in two steps. First, the axi-cylindrical static corona discharge field was calculated with the finite-element method to deduce the Coulombic body force ρE applied to the air, where ρ is the charge density and E is the electric field, and then the induced ionic wind was calculated with the finite differential method. The calculated pressure distribution on the plate electrode was on the order of 10 Pa which was in good agreement with the measured pressure distribution. The calculated air velocity at the center was several m/s and was confirmed by a time-of-flight experiment and the velocity distribution near the pin electrode also agreed with measurements using a laser Doppler velocimeter. Pressure and wind velocity were increased at high-applied voltage. These results confirm that the ionic wind is the cause of the repulsive force to the pin electrode at the corona discharge.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Electrostatics - Volume 64, Issue 6, June 2006, Pages 400–407
نویسندگان
, , ,