کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
736101 893714 2011 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A calibration method for stereo vision sensor with large FOV based on 1D targets
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی برق و الکترونیک
پیش نمایش صفحه اول مقاله
A calibration method for stereo vision sensor with large FOV based on 1D targets
چکیده انگلیسی

Large FOV (field of view) stereo vision sensor is of great importance in the measurement of large free-form surface. Before using it, the intrinsic and structure parameters of cameras should be calibrated. Traditional methods are mainly based on planar or 3D targets, which are usually expensive and difficult to manufacture especially for large dimension ones. Compared to that the method proposed in this paper is based on 1D (one dimensional) targets, which are easy to operate and with high efficiency. First two 1D targets with multiple feature points are placed randomly, and the cameras acquire multiple images of the targets from different angles of view. With the fixed angle between vectors defined by the two 1D targets we can establish the objective function with intrinsic parameters, which can be later solved by the optimization method. Then the stereo vision sensor with two calibrated cameras is set up, which acquire multiple images of another 1D target with two feature points in unrestrained motion. The initial values of the structure parameters are estimated by the linear method for the known distance between two feature points on the 1D target, while the optimal ones and intrinsic parameters of the stereo vision sensor are estimated with non-linear optimization method by establishing the minimizing function involving all the parameters. The experimental results show that the measurement precision of the stereo vision sensor is 0.046 mm with the working distance of about 3500 mm and the measurement scale of about 4000 mm×3000 mm. The method in this paper is proved suitable for calibration of stereo vision sensor of large-scale measurement field for its easy operation and high efficiency.


► 1D targets are used for calibrating intrinsic and structure parameters of stereo vision.
► 1D targets are arbitrarily placed in the field of view.
► All intrinsic parameters and structure parameters as a whole are optimized.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Optics and Lasers in Engineering - Volume 49, Issue 11, November 2011, Pages 1245–1250
نویسندگان
, , , ,