![عکس صفحه اول مقاله: An electrostatically driven valve-less peristaltic micropump with a stepwise chamber An electrostatically driven valve-less peristaltic micropump with a stepwise chamber](/preview/png/736321.png)
An electrostatically driven valve-less peristaltic micropump for gas chromatography has been developed. A stepwise chamber was first fabricated using a three-dimensional (3D) fabrication technique known as detachment lithography; the stepwise design was intended to decrease the dead volume of the device and the operation voltage by inducing zipping action. The pump itself was fabricated with a silicon substrate and a polyimide (PI) diaphragm and operated by four electrodes with a 4-phase sequencing actuation. The pump was operated in a range starting from a voltage of 60 V and frequency of 4 Hz with a flow rate of 18.2 μl/min, up to a voltage of 90 V at a frequency of 6 Hz with a maximum flow rate of 33.1 μl/min. The results showed that the minimum operating voltage of the stepwise chamber was approximately 30% lower than that of a vertical chamber with the same depth, and the power consumption per unit flow rate was also decreased by about 10%.
► We developed an electrostatic peristaltic gas micropump with a stepwise chamber.
► The stepwise chamber is fabricated by using 3D fabrication technique called detachment lithography.
► The micropump with a stepwise chamber has smaller dead volume and higher flow rate at low frequency regime compared to a vertical chamber.
Journal: Sensors and Actuators A: Physical - Volume 187, November 2012, Pages 183–189