کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
736937 893898 2009 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Study on the lift-off effect of EMAT
موضوعات مرتبط
مهندسی و علوم پایه شیمی الکتروشیمی
پیش نمایش صفحه اول مقاله
Study on the lift-off effect of EMAT
چکیده انگلیسی

Non-contact inspection is the main advantage of the electromagnetic acoustic transducer (EMAT). However, it lowers the transduction efficiency between ultrasonic energy and electromagnetic energy. The lift-off of the transducer has a close relationship with transmitting and receiving ultrasonic signals, because it reduces the magnitude of the alternating magnetic field in the specimen. The distribution and intensity of the alternating magnetic field at different lift-off values are simulated in ANSOFT. The relationship between the lift-off and received signals is analyzed through experiments. Results show that the suitable lift-off value for this specific EMAT system should be around 2 mm, considering both sensitivity and stability of the transducer.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Sensors and Actuators A: Physical - Volume 153, Issue 2, 3 August 2009, Pages 218–221
نویسندگان
, , , ,