کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
737171 | 893916 | 2008 | 8 صفحه PDF | دانلود رایگان |

A wireless stress/strain measurement system is developed by integrating with pressure-sensitive sensors for health monitoring of concrete structures. The pressure-sensitive stress/strain sensors are fabricated by using nickel powder-filled cement-based composite. The wireless stress/strain measurement system integrated with these sensors is tested with compressive stress/strain in the range from 0 MPa/0 μɛ to 2.5 MPa/311.5 μɛ for performance evaluation. Experimental results indicate that the electrical resistivity of pressure-sensitive nickel powder-filled cement-based stress/strain sensors changes linearly and reversibly with the compressive stress/strain, and its fractional change goes up to 42.719% under uniaxial compression. The relationship between input (compressive stress/strain) and output (the fractional change in electrical resistivity) of the wireless stress/strain measurement system integrated with pressure-sensitive sensors is Δρ = −0.16894σ/Δρ = −1336.5ɛ. The wireless stress/strain measurement system can be used to achieve a sensitivity to stress/strain of 16.894% MPa−1/0.13365%μɛ−1 (a gauge factor of 1336.5) and a stress/strain resolution of 150 Pa/0.02 μɛ. The newly developed wireless stress/strain measurement system integrated with pressure-sensitive nickel powder-filled cement-based sensors has such advantages as high sensitivity to stress/strain, high stress/strain resolution, simple circuit and low energy consumption.
Journal: Sensors and Actuators A: Physical - Volume 147, Issue 2, 3 October 2008, Pages 536–543