Quick and reliable estimation of BOD load of beverage industrial wastewater by developing BOD biosensor
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Quick and reliable estimation of BOD load of beverage industrial wastewater by developing BOD biosensor
چکیده انگلیسی

An amperometric biosensor for determination of biochemical oxygen demand in wastewater has been developed to overcome the time consuming monitoring procedures. The performance and stability of the immobilized membrane have been investigated at 37 °C and pH 6.8. Immobilized microbial membranes maintain their stability and activity after intermittent use for 400 cycles when stored at 4 °C in sodium phosphate buffer pH 6.8. The response time of the BOD sensor was only 90 min, being independent of the concentration, and the lower detection limit was 1 mg/l. The obtained BOD values showed correlation with that of the conventional method for BOD determination (BOD5) with a deviation of ±10%. Moreover, the sensor exhibits good repeatability (3.39–4.45%) and reproducibility (1.85–2.25%). Software was added to upgrade this sensor and to make it a promising candidate for online monitoring.