کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
744425 1462084 2015 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Novel sensor for sensitive electrochemical determination of luteolin based on In2O3 nanoparticles modified glassy carbon paste electrode
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Novel sensor for sensitive electrochemical determination of luteolin based on In2O3 nanoparticles modified glassy carbon paste electrode
چکیده انگلیسی


• A novel In2O3 nanoparticles modified glassy carbon paste electrode for determination of luteolin (LU).
• Morphological characterization of the modified electrode.
• Electrochemical parameters of the modified electrode.
• Detection of LU in biological fluids and in thyme as a real sample.
• The statistical analysis for trace assay of LU.

A novel In2O3 nanoparticles modified glassy carbon paste electrode (In2O3NPs/GCPE) was prepared and applied for selective and sensitive electrochemical determination of luteolin (LU). Scanning electron microscopy (SEM) was used for the characterization of In2O3NP modifier and its morphology on the surface of GCPE. The modified electrode showed excellent electrocatalytic activities with respect to LU oxidation, with good reproducibility. The electrochemical parameters such as surface concentration (Γ), electron transfer coefficient (α) and the standard rate constant (ks) of LU at the modified electrode were calculated. Under the optimized experimental conditions, the proposed sensor exhibited a rapid response to LU in a linear range from 9.98 × 10−9 M to 8.84 × 10−8 M LU and a low detection limit was found to be 1.99 × 10−10 M LU. The analytical performance of this sensor was evaluated for the detection of LU in spiked human biological fluids and in thyme as a real sample with good accuracy and precision.

A novel In2O3 nanoparticles modified glassy carbon paste electrode (In2O3NPs/GCPE) was prepared and applied for selective and sensitive electrochemical determination of luteolin (LU) in biological fluids and in thyme as a real sample with good accuracy and precision. The quantification and detection limit of LU at this sensor using SWV mode were 6.64 × 10−10 M and 1.99 × 10 −10 M LU, respectively. In2O3NPs/GCPEs displayed reproducible performances, were highly stable and were not susceptible to interference by common contaminants.Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Sensors and Actuators B: Chemical - Volume 206, January 2015, Pages 744–752
نویسندگان
, ,