کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
750730 1462080 2015 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A feasibility study on the non-invasive analysis of bottled Compound E Jiao oral liquid using near infrared spectroscopy
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
A feasibility study on the non-invasive analysis of bottled Compound E Jiao oral liquid using near infrared spectroscopy
چکیده انگلیسی


• A non-invasive analysis method was built for bottled Compound E Jiao oral liquid.
• Laboratory samples were prepared by a concentrating-diluting method.
• NIRS-based PLS calibration models were established for the 3 quality indicators.
• Monte Carlo cross validation was used for the model optimizing.

The aim of this study was to explore the feasibility of near infrared (NIR) spectroscopy for the quantitative analysis of Compound E Jiao oral liquid, a popular oral TCM preparation, through intact glass vials. Transmission spectra were acquired with a sample holder tailored to the instrument's sample compartment. Total flavonoids, total saponins and soluble solid contents were considered as quality indicators of this oral preparation and calibration models were built using partial least-squares regression (PLSR) algorithm. The sample set was comprised of production samples as well as laboratory samples prepared by a concentrating-diluting method so as to extend the concentration range beyond the production variation. The developed models gave root mean square error of prediction (RMSEP) of 0.084 mg mL−1 for total flavonoids, 0.014 mg mL−1 for total saponins and 0.21% for soluble solid contents. To better evaluate the prediction performance, an independent set of ten production samples was introduced for the external validation. The models are compared with those built with the transflectance spectra collected in the destructive way. The results of paired t-test and F-test at a significance level of 0.05 revealed that the two sets of models exhibited comparable model performance. The overall results demonstrate that the proposed non-destructive method can be used as an advantageous alternative in the quality inspection of Compound E Jiao oral liquid production.

In this paper, we report a NIRS-based method for the determination of three quality indicators (viz. total flavonoids, total saponins and soluble solid contents) in Compound E Jiao oral liquid, a popular oral TCM preparation, through intact glass vial. The overall results demonstrate that the proposed method can be used as an advantageous alternative in the quality inspection of Compound E Jiao oral liquid production.Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Sensors and Actuators B: Chemical - Volume 211, May 2015, Pages 131–137
نویسندگان
, , , , ,