کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
755359 1462524 2012 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Analysis and Testing of Microvibrations Produced by Momentum Wheel Assemblies
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی هوافضا
پیش نمایش صفحه اول مقاله
Analysis and Testing of Microvibrations Produced by Momentum Wheel Assemblies
چکیده انگلیسی

The microvibrations produced by momentum wheel assemblies (MWA) can degrade the performance of instruments with high pointing precision and stability on spacecraft. This paper concentrates on analyzing and testing the microvibrations produced by MWA. We analyze the disturbance sources produced by mass imbalance, structural mode, bearing irregularity and nonlinear stiffness, and random noise; then, test a well-balanced MWA by a highly sensitive measurement system consisting of a Kistler table and an optical tabletop. The results show that the test system has a resolution of less than 0.003 N in the frequency range of 3–300 Hz. The dynamic imbalance of the MWA cannot excite the radial rocking mode, but there are dynamic amplifications when the poly-harmonic disturbances intersect with the structural modes. Especially at high rotational speed (>3 000 rev/min), the main disturbance sources of the MWA come from the bearing irregularity interacting with radial translation mode in the high frequency range. Thus, bearing noise deserves more attention for the well-balanced MWA, and alternative of high quality bearings are proposed to reduce the microvibrations.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Chinese Journal of Aeronautics - Volume 25, Issue 4, August 2012, Pages 640-649