A method is proposed in this paper to assess the axis motion errors of a trunnion-type A-axis using the magnetic double ball bar (DBB) as the measuring instrument. The proposed method consists of five DBB tests with a single setup for all of the tests and the exclusive motion of the trunnion axis during data acquisition. The single setup helps to reduce non-productive time by limiting the intervention of the operator within the machine workspace whereas the exclusive trunnion axis motion prevents the data from being contaminated by other axes motion errors within each test. Simulations show that setup errors cause eccentricities and radius changes of the ball bar data when viewed on a polar plot. Finally, the proposed method is applied to a VL30 Mitsui-Seiki vertical machine tool to identify its trunnion axis motion errors. The results show the effectiveness of the proposed method as well as its ease of use and the short time required.
Journal: International Journal of Machine Tools and Manufacture - Volume 46, Issue 14, November 2006, Pages 1823–1834