• A hybrid magnetic refrigerator combined with Stirling refrigeration was designed.
• A centric Halbach cylinder permanent magnet was used in the hybrid machine.
• An optimal phase angle of this hybrid system was figured out.
• The temperature spans improved by 24% in the hybrid machine.
The experimental prototype described in this work is a hybrid refrigerator that combines the active magnetic refrigeration effect with the Stirling gas regenerative refrigeration effect. In this prototype, gadolinium sheets are packed in the regenerator matrix for both Stirling and active magnetic regenerative refrigeration. Experimental tests were carried out to measure the cooling performance of this hybrid prototype. The influence of the phase angle on the cooling performance was investigated, and a reasonable phase angle of 90° was determined to obtain optimal cooling performance. By combining the two refrigeration effects, a minimum cooling temperature without heat load of 3.5 °C was reached, which is lower than that of 6.5 °C for the pure Stirling refrigeration effect without the magnetic cooling effect. The results of this study show that the cooling performance is improved by 24% for the hybrid effects compared with that exploiting only the Stirling gas refrigeration effect.
Figure optionsDownload as PowerPoint slide
Journal: International Journal of Refrigeration - Volume 36, Issue 5, August 2013, Pages 1465–1471