کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
787290 1466452 2011 14 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Experimental analysis of a two-material active magnetic regenerator
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی مکانیک
پیش نمایش صفحه اول مقاله
Experimental analysis of a two-material active magnetic regenerator
چکیده انگلیسی

Experimental results of an active magnetic regenerator (AMR) composed of two equal volumes of gadolinium and Gd0.85Er0.15 using 2 T and 5 T are reported. Drive forces and system losses are measured as a function of thermal load and magnetic field. Metrics for coefficient of performance and efficiency are defined and used to distinguish between regenerator and device performance. Results suggest the largest temperature spans are expected to occur when each material is operating with its average temperature near their Curie temperatures. Force measurements indicate that mechanical losses and pumping power are the most significant contributions to network while the net magnetic work is too small to be resolved. COP values for the magnetic cycle are as high as 2.4 while efficiencies are all less than 0.15. A maximum exergetic cooling of 1.94 W is estimated with a corresponding specific exergetic cooling power of 23 W T−1L−1.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Refrigeration - Volume 34, Issue 1, January 2011, Pages 178–191
نویسندگان
, , ,