The aim of present experimental research is to find out the suitable correlations for designing the coiled finned-tube heat exchangers used in cryogenic applications. In order to conduct above experimental study, cross-counter-flow coiled finned-tube heat exchangers were developed in our lab and used in actual refrigeration cycle. The experiments were conducted in the range of effective Reynolds number 500–1900. The effect of diametrical clearance on the prediction of overall heat transfer coefficient is also investigated experimentally. The results from present study were compared in the form of overall heat transfer coefficient. Results of present experimental research indicate that different correlations selected in the study can be used with reasonable accuracy for designing the coiled finned-tube heat exchangers, if they are applied with suitable method of calculation of free-flow cross-sectional area. A more accurate new correlation has also been proposed that fitted experimental data within ±10% error band.
Journal: International Journal of Refrigeration - Volume 32, Issue 5, August 2009, Pages 960–972