Experimental and numerical investigation of the influence of the two-phase ejector geometry on the performance of the R744 heat pump
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی مکانیک
پیش نمایش صفحه اول مقاله
Experimental and numerical investigation of the influence of the two-phase ejector geometry on the performance of the R744 heat pump
چکیده انگلیسی

An experimental and numerical investigation of the optimum ejector geometry for a small-capacity R744 heat pump was performed. Different ejector configurations were examined, including various lengths and diameters of the mixer and various angles of divergence for the diffuser. Based on a simplified, one-dimensional ejector model, an optimisation of the ejector geometry was performed. Based on both the numerical simulation and experimental work, the ejector efficiency proved to be notably dependent on the mixer length and the diameter, as well as on the diffuser divergence angle. The maximum increase in the coefficient of performance (COP) was 8% over a system with a conventional expansion valve.


► A transcritical R744 system with ejector offered an 8% COP improvement.
► The optimum diffuser divergence angle was found between 3 ° and 5 °.
► The optimum mixer diameter was found between 3 mm and 3.5 mm.
► The optimum mixer length was found between 15 mm and 30 mm.