کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
789769 1466458 2010 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Comparison of CO2 heat pump water heater performance with baseline cycle and two high COP cycles
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی مکانیک
پیش نمایش صفحه اول مقاله
Comparison of CO2 heat pump water heater performance with baseline cycle and two high COP cycles
چکیده انگلیسی

A CO2 heat pump water heater breadboard facility was built and a performance evaluation was conducted to investigate the effect of ambient temperature and hot water temperature on the overall coefficient of performance (COP) during full tank heating tests in three scenarios typical of residential water heating. Results show that the overall COP was maximized at higher ambient temperatures and at lower hot water temperatures. The overall COP was 30% higher for heating a full tank of cold water than reheating a warm tank water after standby losses. Additionally, potential COP enhancements of two cycle options were investigated. Performance enhancement of the two-stage cycle with internal heat exchanger was found only for standby loss reheating at low ambient temperatures and was 7.5%, while that of the suction line heat exchanger cycle was up to 7.9% for initial tank water heating and around 3.4% for reheating a warm tank water.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Refrigeration - Volume 33, Issue 3, May 2010, Pages 635–644
نویسندگان
, , ,