کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
8481957 1551497 2018 27 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Pharmacodynamics and pharmacokinetics of insulin aspart assessed by use of the isoglycemic clamp method in healthy cats
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم کشاورزی و بیولوژیک علوم دامی و جانورشناسی
پیش نمایش صفحه اول مقاله
Pharmacodynamics and pharmacokinetics of insulin aspart assessed by use of the isoglycemic clamp method in healthy cats
چکیده انگلیسی
The objective of this study was to determine the pharmacodynamics (PD) and pharmacokinetics (PK) of insulin aspart in healthy cats following intramuscular (IM) and subcutaneous (SC) injection. Eight healthy, purpose-bred cats were used in a randomized, crossover study design. Each cat had 2 isoglycemic clamps performed, one after receiving 0.25 IU/kg of insulin aspart by IM injection and one after receiving the same dose by SC injection. The two isoglycemic clamps were performed on different days, at least 48 h apart. The blood glucose, plasma endogenous insulin, and plasma insulin aspart concentrations were measured and the glucose infusion rate (GIR) was recorded during the clamp. The GIR over time was used to create a time-action curve for each clamp which was used to describe the PD of insulin aspart. Data that are normally distributed are reported as mean ± SD, while data that are not normally distributed are reported as median (25-75 percentile). When compared to the PD data that have been reported for regular insulin in healthy cats, insulin aspart had a more rapid onset (IM: 10 min [10-21.25 min], SC: 12.5 min [10-18.75 min]) and shorter duration of action (IM: 182.5 ± 34.33 min, SC: 159.38 ± 41.87 min). The onset of action (P = 0.795), time to peak action (P = 0.499), duration of action (P = 0.301), and total metabolic effect (P = 0.603) did not differ with route of administration; however, SC administration did result in a higher maximum plasma insulin aspart concentration (IM: 1,265.17 pmol/L [999.69-1,433.89 pmol/L], SC: 3,278.19 pmol/L [2,485.29-4,132.01 pmol/L], P = 0.000) and larger area under the insulin aspart vs time curve (IM: 82,662 ± 30,565 pmol/L, SC: 135,060 ± 39,026 pmol/L, P = 0.010). Insulin aspart has a rapid onset of action and short duration of effect in healthy cats when administered by IM and SC injection. Although it cannot be assumed that the PD and PK of insulin aspart will be the same in cats with diabetic ketoacidosis (DKA), our data support further investigation into the use of SC insulin aspart as an alternative to regular insulin for the treatment of DKA in cats.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Domestic Animal Endocrinology - Volume 62, January 2018, Pages 60-66
نویسندگان
, , , ,