کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
8502221 | 1553967 | 2014 | 9 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Kinematics as objective tools to evaluate lameness phases in multiparous sows
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
موضوعات مرتبط
علوم زیستی و بیوفناوری
علوم کشاورزی و بیولوژیک
علوم دامی و جانورشناسی
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
Lameness has been ranked as the third most common reason for culling sows, comprising 15% of the culls marketed in the U.S. Producers assess sow lameness using subjective evaluation, which have been shown to be variable in their application. Objective empirical tools to measure sow lameness on farm are required. Therefore, the purpose of this study were to evaluate the embedded force plate and the GAITFour gait analysis walkway system as objective assessment tools to discriminate between sound and lame phases in multiparous sows. Twenty-four mixed parity crossbred sows were anesthetized and injected with Amphotericin B in the distal interphalangeal joint of both claws of one hind hoof to induce transient lameness. Kinematic data was collected on Dâ1, D+1 and D+6 relative to induction (D0). For the embedded force plate, weight distributions on each hoof were collected. Gait analysis measures collected were stride time (defined as the time (s) between 2 successive footfalls by the same hoof), stride length (defined as the distance (cm) between 2 sequential footfalls from the same hoof), maximum pressure (defined as the greatest amount of weight (kg/cm2) placed on a single hoof) and stance time (defined as the duration of time (s) the sensors were activated by a hoof in a single stride). For the embedded microcomputer-based force plate system weight placed on the induced hoof decreased on D+1 when compared to Dâ1 (P<0.0001). For the GAITFour® pressure mat gait analysis walkway system, stride time increased on D+1 for all hooves, stride length decreased on D+1 compared to Dâ1 and maximum pressure placed on the induced hoof decreased on D+1 compared to baseline levels (P<0.05). Stance time increased for all sound hooves on D+1 compared to Dâ1 (P<0.05). In conclusion, the embedded force plate and GAITFour walkway system all demonstrated differences for mature sows during sound and most lame phases indicating promise as objective tools for use on farm.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Livestock Science - Volume 165, July 2014, Pages 120-128
Journal: Livestock Science - Volume 165, July 2014, Pages 120-128
نویسندگان
C.M. Mohling, A.K. Johnson, J.F. Coetzee, L.A. Karriker, C.E. Abell, S.T. Millman, K.J. Stalder,