کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
9041907 1134606 2005 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Factors Affecting Hemolysis Rates in Blood Samples Drawn From Newly Placed IV Sites in the Emergency Department
موضوعات مرتبط
علوم پزشکی و سلامت پرستاری و مشاغل بهداشتی امداد اورژانس
پیش نمایش صفحه اول مقاله
Factors Affecting Hemolysis Rates in Blood Samples Drawn From Newly Placed IV Sites in the Emergency Department
چکیده انگلیسی
Clinically meaningful factors associated with hemolysis rates included the use of a 22-gauge intravenous catheter size, which resulted in a hemolysis rate of 60%; in addition, intravenous placement sites on the right side had statistically significant higher hemolysis rates than the left side, a finding that merits further research. As a result of the study we modified our standard operating procedure to discontinue the use of a 22-gauge or smaller intravenous catheter in adults. If required for small vein sticks, the use of a straight needle stick to obtain blood samples should be considered. The results of this study underscore the importance of education and training and the consideration for regular competency testing for staff with phlebotomy responsibilities.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Emergency Nursing - Volume 31, Issue 4, August 2005, Pages 338-345
نویسندگان
, , , , , , , , , , , ,