کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
10420464 904998 2005 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Influence of measured objects parameters on CMM touch trigger probe accuracy of probing
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی صنعتی و تولید
پیش نمایش صفحه اول مقاله
Influence of measured objects parameters on CMM touch trigger probe accuracy of probing
چکیده انگلیسی
Influence of the measured objects parameters on coordinate measuring machine (CMM) touch trigger probe inaccuracy of probing is investigated. Factors such as material stiffness of measured workpiece, its surface shape and roughness are taken into consideration. The measuring method out off CMM, based on a rotary table and a reference axis is applied for tests. The concept is based on measurements of the distance between reference and triggering points in various directions. The reference points are established by the rotation of a precise rotary table. The statistical analysis of variance and regression is applied for data analysis.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Precision Engineering - Volume 29, Issue 3, July 2005, Pages 290-297