کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
10428581 909254 2015 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Hartmann-Shack sensor based micro-scanning image detection
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی (عمومی)
پیش نمایش صفحه اول مقاله
Hartmann-Shack sensor based micro-scanning image detection
چکیده انگلیسی
A single optical wedge micro-scanning system was designed and added to a Hartmann sensor by analyzing Hartmann-Shack sensor wave-front theory and micro-scanning technology. Micro-scanning overcame the lack of detection accuracy caused by small numbers of pixels in the detector, which gave the Hartmann-Shack sensor high-precision detection with a low number of pixels. Combined with a wave-front reconstructed algorithm and micro-scanning reconstructed high-resolution algorithm, the results were achieved using Lighttools and Zemax software. The wave-front reconstruction accuracy of three CCD detectors which are added to micro-scanning device can raise 72.55%, 32.47%, 0.48%.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Optik - International Journal for Light and Electron Optics - Volume 126, Issue 6, March 2015, Pages 609-613
نویسندگان
, , , , , ,