کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
10432656 | 910256 | 2012 | 8 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Influence of stent configuration on cerebral aneurysm fluid dynamics
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
سایر رشته های مهندسی
مهندسی پزشکی
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
Embolic coiling is the most popular endovascular treatment available for cerebral aneurysms. Nevertheless, the embolic coiling of wide-neck aneurysms is challenging and, in many cases, ineffective. Use of highly porous stents to support coiling of wide-neck aneurysms has become a common procedure in recent years. Several studies have also demonstrated that high porosity stents alone can significantly alter aneurysmal hemodynamics, but differences among different stent configurations have not been fully characterized. As a result, it is usually unclear which stent configuration is optimal for treatment. In this paper, we present a flow study that elucidates the influence of stent configuration on cerebral aneurysm fluid dynamics in an idealized wide-neck basilar tip aneurysm model. Aneurysmal fluid dynamics for three different stent configurations (half-Y, Y and, cross-bar) were first quantified using particle image velocimetry and then compared. Computational fluid dynamics (CFD) simulations were also conducted for selected stent configurations to facilitate validation and provide more detailed characterizations of the fluid dynamics promoted by different stent configurations. In vitro results showed that the Y stent configuration reduced cross-neck flow most significantly, while the cross-bar configuration reduced velocity magnitudes within the aneurysmal sac most significantly. The half-Y configuration led to increased velocity magnitudes within the aneurysmal sac at high parent-vessel flow rates. Experimental results were in strong agreement with CFD simulations. Simulated results indicated that differences in fluid dynamic performance among the different stent configurations can be attributed primarily to protruding struts within the bifurcation region.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Biomechanics - Volume 45, Issue 3, 2 February 2012, Pages 440-447
Journal: Journal of Biomechanics - Volume 45, Issue 3, 2 February 2012, Pages 440-447
نویسندگان
M. Haithem Babiker, L. Fernando Gonzalez, Justin Ryan, Felipe Albuquerque, Daniel Collins, Arius Elvikis, David H. Frakes,