کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
10622838 989313 2005 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Development of a galvanic sensor system for detecting the corrosion damage of the steel embedded in concrete structure
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی صنعتی و تولید
پیش نمایش صفحه اول مقاله
Development of a galvanic sensor system for detecting the corrosion damage of the steel embedded in concrete structure
چکیده انگلیسی
In this study, the results of corrosion behavior of reinforcing steel showed a consistence among the data obtained by open-circuit potential monitoring, LPR and EIS measurements. Steel/copper sensor showed a good correlation in concrete environment between sensor output and corrosion rate of steel bar. However, there was no relationship between steel/stainless steel sensor output and corrosion rate of steel bar due to the low galvanic current output. Through the relationship between the steel/copper sensor output and the corrosion rate of reinforcing steel, the real corrosion damage of the reinforcing steel can be detected. Consequently, this confirms that the galvanic sensor system is a good method for detection of corrosion in reinforced concrete.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Cement and Concrete Research - Volume 35, Issue 9, September 2005, Pages 1814-1819
نویسندگان
, , , ,