کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
10673576 1010258 2008 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Spectroscopic measurement of arc plasma diameter in EDM
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی صنعتی و تولید
پیش نمایش صفحه اول مقاله
Spectroscopic measurement of arc plasma diameter in EDM
چکیده انگلیسی
This paper describes the spectroscopic measurement of arc plasma diameter in EDM. In order to determine the diameter of the arc plasma area where discharge current flows, radial temperature distribution in plasma generated by a single pulse discharge was measured using spectroscopy, and the area with high degree of ionization was determined. It was found that arc plasma completes expanding within a few microseconds after dielectric breakdown, while the diameter of craters grows slowly in comparison with the expanding speed of the arc plasma. This new finding is different from conventional plasma expansion models established based on the observation of generated craters and unproven assumptions. Furthermore, increase in arc plasma diameter with increasing discharge current or gap width was quantified, enabling accurate simulation of discharge crater generation using the newly established heat source model.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: CIRP Annals - Volume 57, Issue 1, 2008, Pages 203-207
نویسندگان
, , ,