کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
10674797 | 1010449 | 2013 | 9 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
The FRS Ion Catcher - A facility for high-precision experiments with stopped projectile and fission fragments
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
مهندسی مواد
سطوح، پوششها و فیلمها
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
At the FRS Ion Catcher at GSI, projectile and fission fragments are produced at relativistic energies, separated in-flight, range-focused, slowed down and thermalized in a cryogenic stopping cell. A multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) is used to perform direct mass measurements and to provide an isobarically clean beam for further experiments, such as mass-selected decay spectroscopy. A versatile RF quadrupole transport and diagnostics unit guides the ions from the stopping cell to the MR-TOF-MS, provides differential pumping, ion identification and includes reference ion sources. The FRS Ion Catcher serves as a test facility for the Low-Energy Branch of the Super-FRS at the Facility for Antiproton and Ion Research (FAIR), where the cryogenic stopping cell and the MR-TOF-MS will be key devices for the research with stopped projectile and fission fragments that will be performed with the experiments MATS and LaSpec. Off-line tests of the stopping cell yield a combined ion survival and extraction efficiency for 219Rn ions of about 30% and an extraction time of about 25Â ms. The stopping cell and the MR-TOF-MS were commissioned on-line as part of the FRS Ion Catcher. For the first time, a stopping cell for exotic nuclei was operated on-line at cryogenic temperatures. Using a gas density almost two times higher than ever reached before for a stopping cell with RF ion repelling structures, various 238U projectile fragments were thermalized and extracted with very high efficiency. Direct mass measurements of projectile fragments were performed with the MR-TOF-MS, among them the nuclide 213Rn with a half-life of 19.5Â ms only.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms - Volume 317, Part B, 15 December 2013, Pages 457-462
Journal: Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms - Volume 317, Part B, 15 December 2013, Pages 457-462
نویسندگان
W.R. PlaÃ, T. Dickel, S. Purushothaman, P. Dendooven, H. Geissel, J. Ebert, E. Haettner, C. Jesch, M. Ranjan, M.P. Reiter, H. Weick, F. Amjad, S. Ayet, M. Diwisch, A. Estrade, F. Farinon, F. Greiner, N. Kalantar-Nayestanaki, M.I. Yavor,