کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
107061 161743 2012 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Forensic utility of carbon isotope ratio variations in PVC tape backings
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Forensic utility of carbon isotope ratio variations in PVC tape backings
چکیده انگلیسی

Forensic interest in adhesive tapes with polyvinyl chloride (PVC) backings (electrical tape) derives from their use in a variety of illicit activities. Due to the range of physical characteristics, chemical compositions, and homogeneity within a single roll of tape, traditional microscopic and chemical analyses can offer a high degree of discrimination between tapes, permitting the assessment of potential associations between evidentiary tape samples. The carbon isotope ratios of tapes could provide additional discrimination among tape samples. To evaluate whether carbon isotope ratios may be able to increase discrimination of electrical tapes, particularly with regards to different rolls of tape of the same product, we assessed the δ13C values of backings from 87 rolls of PVC-based black electrical tape (~ 20 brands, > 60 products) Prior to analysis, adhesives were removed to prevent contamination by adhering debris, and plasticizers were extracted because of concern over their potential mobility. This result is consistent with each of these tapes having approximately the same plasticizer δ13C value and proportion of carbon in these plasticizers. The δ13C values of the 87 PVC tape backings ranged between − 23.5 and − 41.3 (‰, V-PDB), with negligible carbon isotopic variation within single rolls of tape, yet large variations among tape brands and tape products. Within this tape population, carbon isotope ratios permitted an average exclusion power of 93.7%, using a window of +/−0.3‰; the combination of carbon isotope ratio measurement with additional chemical and physical analyses raises the discrimination power to over 98.9%, with only 41 out of a possible 3741 pairs of tape samples being indistinguishable. There was a linear relationship between the δ13C value of tape backings and the change in δ13C value with the extraction of plasticizers. Analyses of pre- and post-blast tape sample pairs show that carbon isotope signatures are within 0.3‰ of pre-blast values, indicating that carbon isotope values are largely preserved during an explosion.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Science & Justice - Volume 52, Issue 1, March 2012, Pages 25–32
نویسندگان
, , , , , ,