کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
10715914 1027380 2010 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Detection efficiency for an ultraviolet photon counting imaging system based on the Ge induction readout
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم ابزار دقیق
پیش نمایش صفحه اول مقاله
Detection efficiency for an ultraviolet photon counting imaging system based on the Ge induction readout
چکیده انگلیسی
The detection efficiency, assumed proportional to the count rate, of an ultraviolet photon counting imaging system based on the Ge induction readout is studied. For the Ge induction readout, the system count rate with different Ge layer resistances, Ge layer thicknesses and ceramic thicknesses are tested under different light intensities. The test results show that the system count rate with a high resistance in the Ge layer is lower than that with a low resistance in the Ge layer; further, the imaging area decreases as the Ge layer resistance increases under high photon flux. Moreover the system count rate with a thick Ge layer is lower than that with a thin Ge layer. In addition, the system count rate with 2-mm ceramic is higher than that with 1.5- and 3-mm ceramic. The above observation should be considered when designing an ultraviolet photon counting imaging detector based on the Ge induction readout.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 622, Issue 1, 1 October 2010, Pages 311-315
نویسندگان
, , , , ,