کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1143775 1489609 2015 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Ergonomics and Workflow Evaluation of Automatic Doppler Angle Technology Implemented in a Diagnostic Ultrasound System
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی صنعتی و تولید
پیش نمایش صفحه اول مقاله
Ergonomics and Workflow Evaluation of Automatic Doppler Angle Technology Implemented in a Diagnostic Ultrasound System
چکیده انگلیسی

Commonly available Pulsed Wave Doppler (PW) flow velocity measurements for Ultrasound (US) investigation require the operator to manually set the direction of the flow velocity vector along the blood vessel axis on the US image, in order to determine the Doppler angle and then to estimate the real flow velocity. The present work investigates the possibility to implement on a commercially available US system an innovative Automatic Doppler Angle (ADA) Technology by analyzing the best workflow in terms of higher execution speed, lower keystrokes/adjustments helping in the prevention of Work-related Musculoskeletal Disorders (WRMSD) and a Doppler angle correction precision, comparable to the one obtained manually by expert sonographer. Ergonomics and workflow tests, then accuracy and repeatability evaluations of the Doppler velocity measurement, were performed on a portable US system (MyLabAlpha, Esaote S.p.A., Florence, Italy) by an expert sonographer. Ergonomics and workflow Tests were performed to analyze the potential of ADA in terms of reduction of muscular activation applied (by SEMG), number of activations (by cameras optoelectronic system) and time needed using ADA, in comparison to manual procedure. Accuracy and intra-operator repeatability tests of the velocity measurement were performed to evaluate the precision of the obtained PW trace velocity measurements with ADA technology, compared to manual ones. Results provided evidence that ADA tool allowed: a reduction of muscular activation (from 12% for trapezius descendens, to 25% for deltoideus anterior) a lower total number of keystrokes and a reduction of the US scan time of about 56%. The maximal variation between PW Doppler trace velocity measurement set automatically by ADA and set manually by sonographer was 11%. ADA technology can provide a Doppler angle correction precision comparable to the manual one, while decreasing the risk of WRMSD.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Procedia Manufacturing - Volume 3, 2015, Pages 120-127