کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1149346 | 957874 | 2013 | 10 صفحه PDF | دانلود رایگان |
For systems with hidden or unrevealed failures, a common practice is to inspect the system regularly, since failures can only be detected upon inspection. Recent works in the literature have studied the availability of a system under periodic inspection, assuming perfect repair/replacement with non-negligible downtime due to repair/replacement for a detected failure. In some situations, however, not only downtime due to repair/replacement but also downtime due to inspection is non-negligible regardless whether a failure was detected or not. In this paper, we consider the availability of a system subject to hidden failure inspected at constant interval with both non-negligible downtime due to inspection and non-negligible downtime due to repair/replacement.
Journal: Journal of Statistical Planning and Inference - Volume 143, Issue 1, January 2013, Pages 176–185