کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1254145 971349 2014 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Imidazolium ionic liquid as the background ultraviolet absorption reagent for determination of morpholinium cations by high performance liquid chromatography-indirect ultraviolet detection
ترجمه فارسی عنوان
مایع یونیزاسیون ایزادیمال به عنوان پسزمینه جذب کننده اشعه ماوراء بنفش برای تعیین کاتیون مورفولینیم با استفاده از کروماتوگرافی مایع کروماتوگرافی با کارایی بالا - غیر مستقیم فرآیند شناسایی ماوراء بنفش
کلمات کلیدی
کروماتوگرافی مایع با کارایی بالا، تشخیص فرابنفش غیر مستقیم، مایعات یونی ایزادولیوم، کاتیون مورفولینیم
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی (عمومی)
چکیده انگلیسی

A novel analytical method was developed for determining morpholinium cations lacking ultraviolet absorption groups. This determination was carried out by high performance liquid chromatography-indirect ultraviolet (HPLC-IUV) detection using imidazolium ionic liquid as background absorption reagents, and imidazolium ionic liquid aq. soln.–organic solvent as mobile phase by a reversed-phase C18 column. The background ultraviolet absorption reagents, imidazolium ionic liquids and organic solvents were investigated. The imidazolium ionic liquid in the mobile phase is not only the background ultraviolet absorption reagent for IUV, but also an active component to improve the separation of morpholinium cations. It was found that morpholinium cations could be adequately determined when 0.5 mmol/L 1-ethyl-3-methylimidazolium tetrafluoroborate aq. soln./methanol (80:20, v/v) was used as mobile phase with an IUV detection wavelength of 210 nm. In this study, the baseline separation of N-methyl, ethylmorpholinium cations (MEMo) and N-methyl, propylmorpholinium cations (MPMo) was successfully achieved in 8.5 min. The detection limits (S/N = 3) for MEMo and MPMo were 0.15 and 0.29 mg/L, respectively. This simple and practical method has been successfully applied to the determination of two morpholinium ionic liquids synthesized by the chemistry laboratory.

Utilizing imidazolium ionic liquid as the background ultraviolet (UV) absorbing reagent, the determination of morpholinium cations is achieved by high performance liquid chromatography with indirect ultraviolet detection (HPLC-IUV).Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Chinese Chemical Letters - Volume 25, Issue 10, October 2014, Pages 1371–1374
نویسندگان
, , ,